vPad-IV is the future of Infusion Device Testing!

Our intuitive modern design is merely the beginning as it features several first, including the ability to conduct up to six preventive maintenance inspections on different devices at the same time. vPad-IV is an expandable modular system producing on-device user-managed automated testing and many other standard features that customers using our vPad platform are familiar with.

This flexible system allows you to start with a single channel today and slowly add more channels over time to meet your testing needs.

Product Details

Key Features

■Conforms to all IEC 60601-2-24 test requirements for Infusion Pumps & Pump Controllers
■Modular, expandable system can be arbitrarily configured as 1 to 6 channels
■Completely independent channels enable differing tests and inspections to be executed simultaneously
■Automatic or Manual Flow, Piggyback/KVO, PCA Pumps, and Occlusion Pressure tests
■Automated test setups provide user-defined pass/fail conditions
■User-managed test sequences combine PM Checklists and Automated Testing
■Large 10” high-resolution LCD touch screen ■Integrates with existing vPad platform
■Full-range class-leading accuracy from 0.1 - 3000 ml/hr

vPad-IV

Flow Measurement

  • Nominal range: 0.1 – 3000 ml/hr
  • Maximum flow displayed: 3200 ml/hr Minimum flow displayed: 0.01 ml/hr
  • Maximum display resolution: 0.001 ml/hr
  • Accuracy (Average flow):
    • ±(1% + 0.005 ml/hr) at 0.1 – 9.9 ml/hr for volume > 100μl;
    • ±1% at 10 – 1200 ml/hr for volume > 1 ml;
    • ±2% at 1201 – 3000 ml/hr for volume > 10 ml 

Volume Measurement

  • Range: 0.02 – 9999 ml
  • Accuracy:
    • ±(1% + 1 LSD) at 0.1 – 9.9 ml/hr for volume > 100μl;
    • ±(1% + 1 LSD) at 10 – 1200 ml/hr for volume > 1 ml;
    • ±(2% + 1 LSD) at 1201 – 3000 ml/hr for volume > 10 ml
  • Maximum display resolution: 0.01 ml 

Elapsed Time Measurement

  • Range: 0 – 240 hours
  • Accuracy: ±0.5 second
  • Display format: HHH:MM:SS 

PCA Pump or Piggyback (KVO) Measurement

  • Range: See Volume Measurement above
  • Minimum Detectable Bolus or Dose: 0.5 ml
  • Bolus or Dose Uncertainty: ±10 μl for volume > 0.5 ml 

PCA Lockout Time Measurement

  • Range: 1 – 240 minutes
  • Accuracy: ±0.05 minutes 

PCA Pump Trigger Outputs:

  • Mechanical: 3.5 mm mono phono jack
  • Electrical: SPST NO relay contact, 30V, 300 mA 

Pressure Measurement

  • Range: -260 to +2600 mmHg (-5 to +50 psi)
  • Accuracy: ±(1% + 5 mmHg)
  • Units of measure: mmHg, psi, bar, mbar, kPa, in. H2O, torr
  • Barometric compensation: 715 to 1095 mbar 

Fluid Interface

  • Luer lock female (Front)
  • Barbed fitting for 1/8” ID tubing (Rear) 

User Interface

  • High-Resolution Android 10.1” Tablet with Wi-Fi and Bluetooth (Optional) Bluetooth compatible barcode scanner, keyboard, & mouse 

Additional Analyzer Interfaces

Primary Module (Controller):

  • USB Type A (host) – Charging and communication to a vPad tablet
  • USB Type B (device) – Connection to PC
  • RJ45 – vPad-IV communication bus for multi-channel systems
  • RJ12 (DACOM XBUS) – Communication with other Datrend products
  • Bluetooth – Communication to a vPad tablet (standard feature)

Secondary Module:

  • RJ45 (2x) – vPad-IV communication bus 

IEC Standards

  • Enables testing per IEC 60601-2-24: Particular requirements for the basic safety and essential performance of infusion pumps and controllers 

Standard Apps

  • vPad-IV – Provides automatic and manual infusion pump testing Record Manager – Full-featured test record management system Datrend Docs – PDF management app for user and service manuals QuickSupport (TeamViewer) – Tool for remote support and training 

vPad-IV App Key Features 

  • Execute up to 6 infusion device PM inspections simultaneously 
  • Individual Channel and All-Channel Views 
  • Manual or Automatic Testing (Flow, Piggyback/KVO, PCA, Occlusion) 
  • User-configured test criteria enables automatic test pass/fail 
  • User-managed AutoSequences to combine PM checklist steps with automated performance tests 
  • Channel Linking merges test results of multi-channel pumps into one report 
  • Auto-recall equipment information and test or PM procedure based on inventory Control Number 
  • Real-time test graphs and on-device Trumpet Curve analysis… No PC software is required! 

Power Supply

  • 100 – 240 VAC 50/60 Hz @ 60 W 

Dimensions & Weights

  • 1 CH 11.2 x 20.0 x 23.6 cm (4.4 x 7.9 x 9.3 in.) @ 1.34 kg (2.95 lbs.)
  • 2 CH 16.3 x 20.0 x 23.6 cm (6.4 x 7.9 x 9.3 in.) @ 2.32 kg (5.10 lbs.)
  • 3 CH 21.3 x 20.0 x 23.6 cm (8.4 x 7.9 x 9.3 in.) @ 3.30 kg (7.25 lbs.)
  • 4 CH 26.4 x 20.0 x 23.6 cm (10.4 x 7.9 x 9.3 in.) @ 4.28 kg (9.40 lbs.)
  • 5 CH 31.5 x 20.0 x 23.6 cm (12.4 x 7.9 x 9.3 in.) @ 5.26 kg (11.55 lbs.)
  • 6 CH 36.6 x 20.0 x 23.6 cm (14.4 x 7.9 x 9.3 in.) @ 6.24 kg (13.70 lbs.) 

Environment

  • Operating Temp: 15°C to 40°C
  • Storage Temp: -20°C to 50°C
  • Relative Humidity: 10% to 90% non-condensing
  • Indoor Use Only, Category II
  • Max. Altitude 3000 m 

† For continuous flow conditions only 